고층 건물에서의 압력차를 이용한 자연환기 모델 적용 가능성
이중엽, 정성균, 김태연 et al. · 한국생태환경건축학회 학술발표대회 논문집 · 2012
The rapid economic development and industrialization in the Republic of Korea has brought a concentration of popularation in cities since the 1980s. A trend of high-rise buildings has positive aspects such as a convenient life style according to the application of high technology and improvement of local image as the factor of landmark. However, there are various negative aspects compared with low-rise buildings because of external environment. Above all, an increase of energy consumption is big problem which is against the trend of preventing the global warming. In this sense, we should pay attention to improving natural ventilation performance in high-rise buildings. The purpose of this study using a CFD(Computational Fluid Dynamics) simulation is to find resolutions of natural ventilation problems in high-rise buildings. To find a resolution, we make a simple model for CFD and check the distribution of pressure on the model surfaces. the distribution of pressure on the model surfaces has a characteristic that the edge of the model has more (-) pressure than the other surfaces in the model. This means that the (-) pressure can use it for natural ventilation. By connecting a ventilation duct and a room which need natural ventilation, the room can increase a ventilation rate in the room. The verification had proved in this study by CFD.
Cited by 0 works.