Динамика поведения флотирующей части тромба на протяжении острого периода флеботромбоза по данным цветового дуплексного сканирования

Негрей Владимир Фёдорович, А Г Куклин, Андрющенко Игорь Владимирович · Сибирский медицинский журнал (Иркутск) · 2012

In the paper the experience of colour duplex ultrasonic scanning (DUS) of vena cava inferior venous system is discussed. The scanning was carried out in 298 patients with acute deep vein thrombosis, who entered the Department of vessel surgery of the Irkutsk Municipal Clinical Hospital №1 during 2006-2011. DUS of vena cava inferior venous system was carried out to all the patients in entering and in dynamics on the 2, 5, 6, 11 and 12 days. In 250 (83%) of cases a side or occlusive thrombosis of deep veins of low extremities was revealed. The group of 48 (16.1%) patients with floating part of apex of the blood clot was the most interesting for us. The greatest danger of embolism became a reason for careful observation and further analysis of this group. DUS of vena cava inferior venous system was carried out every other day to evaluate the dynamics of floating part of the blood clot in the lumen of vessel. In 6 cases the floating apex of the blood clot was situated in distal part of vena cava inferior, in 4 cases in external ileal vein, in 22 cases in general femoral vein, in 6 cases in femoral vein, in 10 cases in popliteal vein. Standard anticoagulant therapy by low-molecular haeparin in medical doses was carried out during 11-12 days of acute period in all patients. Adequate anticoagulant therapy and ultrasonic control in dynamics permit to transform floating thrombosis into a fixed side thrombosis or into occlusive one.