수중 하베스트 빙축열시스템의 운전특성 실험
최인수, 박창근, 한인근 et al. · 1999
A fundamental study on under water harvest-type ice storage system and its operating characteristics in ice storage system was performed experimentally. The experiments were performed by changing inlet and outlet refrigerant temperature of evaporator to analyzing its characteristics duing operating system in cooling mode. From the experimental results, the operating characteristics of under water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to oprating compressor respect to the change with the inlet and outlet refrigerant temperature of evaporator. In case of underwater harvest-type ice storage system, its characteristics were shown differently in comparison with that of other ice storage system and regular refrigerating system during cooling storage process. Especially, there was no supercooling phenomenon in ice storage tank. These results provide the characteristics of this system and the possibility of application to other fields.
Cited by 0 works.