자동차 점화코일용 합성절연유의 교류 절연파괴 특성

신종열, 조돈찬, 조경순 et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 1997

The AC breakdown characteristics of the synthetic fluids No. 2 of KS class VII used for insulating and cooling the materials for the automotive ignition coil are studied. Also, BTA(Benzotriazole) as the streaming electrification suppressant additive is added to the oil, and the change of electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown. The breakdown strength of specimen by adding BTA is higher than virgin specimen in low temperature region, but lower than that in high region because of melting BTA.