위상 고정 루프의 기준 스퍼를 감소시키기 위한 이중 보상 방식 전하 펌프
이동건, 이정광, 정항근 · 2010
The charge pump in a phase-locked loop is a key block in determining reference spurs of the VCO output signal. To reduce reference spurs, the current mismatch in the charge pump must be minimized. This paper presents a dual compensation method to reduce the current mismatch. The proposed charge pump and PLL were realized in a 0.18㎛ CMOS process. Measured current matching characteristics were achieved with less than 1.4% difference and with the current variation of 3.8% in the pump current over the charge pump output voltage range of 0.35-1.35V at 1.8V. The reference spur of the PLL based on the proposed charge pump was measured to be -71dBc.
Cited by 0 works.