[論文] 피복된 傳熱面에서의 沸騰特性(大氣壓 以下의 壓力에서)

문대영, 오수철, 임장순 · 설비저널 · 1977

This paper describes an experimental investigation which has been carried out with distilled water with the range of heat flux and pressure covering 7,400-28, 000㎉/㎡h and 0.42-1.0332㎏/㎠abs, respectively. In this experiment, Nickel coated mirror surface heater of 5㎝ O.D. was used as a heating source. The conclusions summerized as follows; 1. The useful correlation of the test data for the heat transfer coefficient is presented as a function of the pressure. α/α_s=c×p 0.18 where α is the heat transfer coefficient and α_s is the heat transfer coefficient at atmospheric pressure and p is the pressure, C is constant. 2. The bubble diameter near the heating surface and rising velocity increased with the heat flux. 3. A decrease in pressure results in the decrease of the number of nucleation sites and the increase of the bubble volume. 4. Bubble rising velocity differences are increased maximumly up to 200% of that at atmopheric pressure.

Cited by 1 works.