정전식모 전극을 이용한 전기집진 장치에 있어서 서브미크론 입자의 포집 성능
성봉조, 이성화, 진심원 et al. · 대한설비공학회 하계학술발표회 논문집 · 2007
To improve the collection efficiency of fine particles, electrostatic flocking technique has been employed in this study. This technique is based on increasing surface area of the collecting electrode and on producing gradient force at the tip of fibers to suppress re-entrainment. In this article, an experimental study was performed to evaluate the effect of fine fiber on the collection efficiency of fine particles using the ESP with electrostatic flocking electrodes as collecting plates. The ESP achieved collection efficiency over 94%, which was higher than that of the flat plate electrode for fine particles (0.3-0.5μm in diameter) with a short residence time (0.06s). We confirmed that fine particles agglomerated at the tip of the flocking fibers. These results indicate that the new type ESP examined in this study is effective to improve removal performance of fine particles.
Cited by 0 works.