기존 공동주택의 실내공기질 실태에 관한 측정 연구

이윤규, 김창남 · 대한건축학회 논문집 - 계획계 · 2004

Because of the airtightness of buildings or the misuse of building materials, indoor air pollution has been increasingly concerned. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. Also, Indoor air quality of existing apartment house is poor compared with other country's standards. In this study, to investigate the actual condition of indoor air quality in domestic apartment house, we measured the indoor air pollutant of existing apartment house that pass one or two years since constructed. In formaldehyde case, 50% of total investigation object (average 0.110, max, 0.311 ㎎/㎥), and in TVOC(Total Volatile Organic Compound) case, 72.2% of total existing apartment house(average 0.630, max, 1.198 ㎎/㎥) were excess both WHO and Japan Ministry of Health. Labour and Welfare's guidelines. In each VOCs, indoor concentrations of Toluene, Xylene and Ethylbenzene. Styrene were very high. Indoor concentrations of benzene, trimethylbenzene and tetrachloethylene were quitely high.

Cited by 0 works.

Authors