Computer Simulation and Analysis on Flow Characteristics and Distribution Patterns of Polymethylmethacrylate in Lumbar Vertebral Body and Vertebral Pedicle
Da Liu, Xuli Liu, Bo Zhang et al. · BioMed Research International · 2015
This study was designed to analyze the flow and distribution of polymethylmethacrylate (PMMA) in vertebral body through computer simulation. Cadaveric lumbar vertebrae were scanned through electron beam tomography (EBT). The data was imported into Mimics software to build computational model. Vertebral body center and junction of pedicle and vertebral body were chosen as injection points. Silicone oil with viscosity of 100,000 cSt matching with PMMA bone cement was chosen for injection. The flow and distribution of silicone oil were analyzed using Fluent software. In vertebral body, silicone oil formed a circle-like shape centered by injection point on transverse and longitudinal sections, finally forming a sphere-like shape as a whole. Silicone oil diffused along lateral and posterior walls forming a circle-like shape on transverse section centered by injection point in pedicle, eventually forming a sphere-like shape as a whole. This study demonstrated that silicone oil flowed and diffused into a circle-like shape centered by injection point and finally formed a sphere-like shape as a whole in both vertebral body and pedicle. The flow and distribution of silicon oil in computational model could simulate PMMA distribution in vertebral body. It may provide theoretical evidence to reduce PMMA leakage risk during percutaneous vertebroplasty.
Cited by 6 works. doi:10.1155/2015/160237 Open-access PDF
Authors
References
- Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty
- The characteristics of a hydroxyapatite?chitosan?PMMA bone cement
- An Ex Vivo Biomechanical Evaluation of a Hydroxyapatite Cement for Use With Vertebroplasty
- Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure
- Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors
- Infection after vertebroplasty or kyphoplasty. A series of nine cases and review of literature
- Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration
- Cement Distribution, Volume, and Compliance in Vertebroplasty
- How to determine the permeability for cement infiltration of osteoporotic cancellous bone
- The biomechanics of vertebroplasty: A review