연구론문(硏究論文) : 마이크로-나노버블 및 일반버블 산기장치 시스템의 산소전달효율 비교 연구

한영립, 최영익, 윤태경 et al. · 2011

The main objective of this study was to evaluate the comparative analysis of oxygen transfer efficiencies between MNB(Micro-nano bubble) and CB(conventional bubble) diffuser systems for application of wastewater treatment processes such as flotation, aeration, water reclamation and so on. The bubble size of the MNB diffuser system was shown to be below 0.5 ㎛, and a proper air flowrate was 1.0 L/min. When the proposed MNB system compared with the CB diffuser system, the overall oxygen transfer coefficient (KLa), standard oxygen transfer rate (N) and volumetric oxygen transfer rate (VOTR) values were 11.67 (13.18), 11.80 (13.08) and 3.23 (13.14) times higher for influent (effluent) dyeing wastewater in the same initial conditions at air flow rate (1.0 L/min) under standard conditions (20℃, 1 atm), respectively. Therefore, the MNB diffuser system is expected to be much better effective technology on water and wastewater treatment processes.

Cited by 0 works.