iTECH 보에 대한 내화성능 평가

민정기, 강석원, 김명한 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2004

The story height of the tall buildings has become the significant construction factor due to the limited construction area within the metropolitan city area. iTECH (Innovative Technical Economical & Convenient Hybrid) beam system was developed to reduce story height of residential and commertial building. The iTECH beam system, which is partly encased by the concrete, represents fairly good performance under fire. The temperature distribution of iTECH beam under fire was investigated by using the finite element method in this study. The fire conditions of both ISO standard fire and natural fire were considered. The fire resistance of iTECH beam was identificated by load ratio for more exact quantitative evaluation.