다중계측기법을 이용한 유체누설 정량화 시스템에 관한 연구

김성영, 김영범, 권갑주 et al. · 대한기계학회 춘추학술대회 · 2008

The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plant) decreases efficiency and therefore leads to considerable economic loss due to less power production. Also the leakage possibly damages critical parts of components such as valve and trim and deteriorates its performance. This study identifies the leakage using the acoustic emission method in order to understand the leakage characteristics and to quantify amount of leakage on the valve having same conditions as secondary side valve of YoungKwang unit 1&2. The acoustic emission characteristics indicated considerable leakage over 0-2% damage of valve and the ultrasonic test characteristics indicated considerable leakage over 2-5% damage of valve. The program to quantify leakage and convert it into cost was developed using the database obtained from repeated tests.

Cited by 0 works.