축류압축기의 스톨 발단에 관한 연구

임형수, 조민기, 강신형 et al. · 유체기계 연구개발 발표회 논문집 · 2008

Experimental research has been observed to investigate stall inception characteristics in 4 stage axial compressor. To analyze instantaneous static pressure signal which was measured using a fast response pressure sensor, the signal was decomposed into shaft resolved component, periodic and aperiodic revolution components for two kinds of flow rates. In both flow rates, shaft order periodicity was confirmed by signal decomposition. However, at low flow rate, the amplitude of aperiodic revolution component was 50 percent bigger than that of high flow rate. It means that at high flow rate, circumferential static pressure field is more stable than low flow rate condition. The compressor performance test was performed in no-stall, stall onset and fully developed stall conditions. Even in stall condition, dimensionless performances of three different shaft speeds were corresponded well. The frequency of shaft order perturbation, mode and fully developed stall were analyzed by frequency analysis methods.

Cited by 0 works.