부분예혼합 및 예혼합 가스기기의 호환성 판정법
김종민, 이승로, 하영철 et al. · KOSCO SYMPOSIUM 논문집 · 2010
An estimation method of the interchangeability using equivalent gases for the partial premixed and premixed gas appliances was suggested and drawn on Dutton and S diagrams, experimentally. For this study, a gas range for the partical premixed appliance and a multi-hole burner of condensing gas boiler for the premixed appliance were used to measure CO mole fraction for incomplete combustion and an flame lifting. As result, for the gas range, incomplete combustion limit (i.e CO mole fraction) was decided on 56.3 MJ/㎥ Wobbe Index which equals to 10 %(95~100 ppm) of the city gas and flame lifting was limited above 51 MJ/㎥ Wobbe Index. Limits of multi-hole burner at equivalence ratio 0.65 and 0.7 were decided on 53 MJ/㎥ and 49.5 MJ/㎥ Wobbe Index, respectively.
Cited by 2 works.