서미스터 유속계 개발에 관한 실험적 연구
차상현, 홍재훈, 조지룡 et al. · 한국자동차공학회 지회 학술대회 논문집 · 2002
This paper introduces a new approach to the measurement of low fluid velocities. A new type of anemometer uses a self-heated thermistor instead of a platinum hot-wire. The principle is based on hot-wire anemometer. To enhance the probe sensitivity to fluid velocity during reducing convection, the thermistor is kept at the lowest possible temperature. The heat removed from the thermistor is expressed by the characteristic function which depends not only on the fluid velocities but also on the fluid temperature. The cross-sensitivity of the probe to the fluid temperature is compensated. This process of temperature compensation and characteristic function makes accurate measurements possible with a simple configuration. The experimental result shows that it is an exact and useful air flow measurement device.
Cited by 0 works.