고력볼트 축력변화에 의한 원전시설물 가새골조의 안전성 평가
강민욱, 김진우, 김선희 et al. · 대한건축학회 학술발표대회 논문집 · 2014
Nuclear facilities braced frame is an efficient system that can acquire resistance against the lateral force of buildings with the least amount of quantity. The axial force of the bolt is a very important factor In applying the braced frame of high-strength bolt friction joint and it is associated with strength. Axial forces of bolt can be degraded by environment condition, long-term axial relaxation, wind·seismic load etc.. The purpose of this study is to examine the stability of braced frames used in nuclear facilities, according to the change of the bolt tightening axial force in the brace and gusset plate joints are used. Also, check the strength of the braced frame by the bolt hole size according to contractors error, bearing behavior.