원유비축기지용 유중펌프의 형상설계
정경남, Jin‐Young Kim, 박종후 et al. · 대한기계학회 춘추학술대회 · 2010
This study deals with hydraulic design of a submergible pump which is installed near the bottom of Ulsan oil stockpiling site. It is used to unload crude oil to a tanker and is run by a 2,800 ㎾ electric motor. This pump has the largest size in the world so far and is a vertical pump with diffuser. Pump design has been carried out by using the analyzed results obtained from the numerical calculations for the effects of several design parameters such as impeller diameter, exit breadth, impeller leading-edge profile, diffuser inlet blade angle, etc. Pump efficiency has been improved by getting rid of flow separation which is generated on the impeller blade due to high pump head and limitation of pump size. NPSH required performance has been improved by applying the above mentioned numerical studies. It has been confirmed from full-scale tests that the pump design is performed satisfactorily.