КОЛИЧЕСТВЕННАЯ ОЦЕНКА ВЛИЯНИЯ РАЗЛИЧНЫХ ФАКТОРОВ НА СТЕПЕНЬ ПОВРЕЖДЕННОСТИ ИЗОЛЯЦИОННОГО ПОКРЫТИЯ ПОДЗЕМНОГО ТРУБОПРОВОДА
В. В. Кравцов, А. В. Старочкин, И. Г. Блинов et al. · 2013
A mathematical model for the assessment of the insulation of underground pipelines, which allows to determine the area of damage. Established the importance of the influence of various factors - the «age» of the pipeline, the diameter and depth of the foundation, the type of insulation, insulation thickness - the degree of damage of the insulation coating, estimated on the testimony of the dial or digital device installation UKI-1M. We previously as a result of statistical analysis of the database-tion obtained from diagnostic examinations insulating coatings, obtained an equation capable of evaluating the area of the defective area in the insulation coating on the testimony of the instrument and the values of total and polarization potentials. The aim of this work is to establish the influence of various factors - «age» of the pipeline (τ0), the diameter (D) and the depth of the (h), of type insulation - bituminous (b) or extruded polyethylene (ep), the thickness of the insulation (δ) - the degree of damage of the insulation coating, estimated on the testimony of the dial or digital device installation UKI-1M.
Cited by 0 works. doi:10.17122/ngdelo-2013-3-88-91