대기압 플라즈마 유동장에 삽입된 랑뮤어 프로브의 영향에 관한 수치적 연구

백재상, 황정훈, 이종철 et al. · 대한기계학회 춘추학술대회 · 2006

Atmospheric arc plasmas have been applied to many kinds of industrial materials processing, including welding, cutting, heating and plasma-treatments. Measurements with Langmuir probes, which are the most often used procedures of the plasma diagnostics, interfere with plasma flows a little. In this study, the thermal and fluid dynamic disturbances caused by the insertion of a Langmuir probe into a flowing thermal plasma and the characteristics of atmospheric arc plasma in the absence of a probe are compared. And the main goal of this work is to investigate the influence of a Langmuir probe on the temperature and velocity fields of the arc through the comparison of two cases by computer simulation. Using a commercial code, PHOENICS which uses the conservation equations and current continuity equation have been solved for the temperature distribution within the solid electrodes with the temperature and velocity fields of the plasma flow, simultaneously.

Cited by 0 works.

Authors