액화가스를 이용한 여러 가지 형상 기화기의 기화특성에 관한 실험적 연구

이용훈, 이상철, 지명국 et al. · 한국동력기계공학회 학술대회 논문집 · 2006

This paper was studied for optimum design of the used vaporizer at a satellite station. Generally, the frozen air is created by temperature drop on the vaporizer surface. In addition, the frost creates ice deposit layer, therefore, heat transfer on vaporizer decreases into the adiabatic condition. By this reason, recent vaporizer system is installed as parallel type, and it takes tree times of vaporizer capacity. But this vaporizer system requires much installation costs and restricted by some space. It is very important to solve this problem. This study paper is regarding air vaporizer where the utilization increases recently. There are three variable conditions which are used in this study research. First, fin lengths of 4000㎜, 6000㎜, 8000㎜ and 0, 4, 8 fin types were applied on each vaporizer. Second, we applied four season condition which consist of humidity, temperature and air velocity to the experimental environment. Finally, pressure was applied to get flow rate during experiment. This paper objective is to propose vaporizer type and length data for best performance of vaporizer through experiment.

Cited by 0 works.