유량함수 내장형 질량유량계에 관한 연구

유성연, 김강식, 김태호 et al. · 대한설비공학회 2014년도 하계학술발표대회 · 2014

In this study, mass flowmeter using a differential pressure nozzle is developed and tested. Flowrate is calculated from the measured pressure and temperature using the embedded flow functions such as isentropic exponent, expansion factor, compressibility factor, density and viscosity. Flowrates measured using the developed flowmeter are compared with those of turbine meter and KRISS calibration flowmeter. The measured error increases as the flowrate increases, and the corrected errors found to be within ±0.5%.

Cited by 0 works.

Authors