최적 핵연료 접촉 열전도도 모델 개발을 위한 예비 연구

양용식, 신창환 · 대한기계학회 춘추학술대회 · 2007

A gap conductance is very important factor which can affect nuclear fuel temperature. Especially, in case of an annular fuel, a gap conductance effect can lead an unexpected heat split phenomena which is caused by a large difference of an inner and outer gap conductance. The gap conductance mechanism is very complicated behavior due to the its strong dependency on microscopic factors such as a contact surface roughness, local contact pressure and local temperature. In this paper, for the decision of test temperature and pressure range, a procedure and calculation results of in-reactor fuel temperature and pressure analysis are summarized which can be applied to test equipment design and determination of test matrix. Based upon analysis results, it is concluded that the minimum and maximum test temperature are 300℃ and 530℃ respectively, and the maximum pellet/cladding interfacial contact pressure should be observed up to 45㎫.

Cited by 1 works.

Authors