Исследование ионной эмиссии натрия в натриевых лампах
V.G. Vasil’chenko, В. К. Свешников · Современные проблемы науки и образования · 2012
Quality control of lamps and improving their design requires establishing of the linkage between the sodium emission current, the diffusion coefficient and other factors. The article shows the dependence of the emission current of sodium ion on the surface of discharge tubes (PT) on the coefficient of diffusion of sodium and duration of work of sodium lamps. The study was conducted on sodium lamps DNaT-400. The discharge tubes were produced of fine-grained polycrystalline alumina and were filled with xenon to a pressure of 2.6 kPa and 2.4 x 10-5kg of 30% sodium amalgam. Ion current leakage of sodium from RT tubes in a given mode of operation increases with the diffusion coefficient and decreases in the course of its work. The difference between the calculated and experimental data is 8%. The results can be used in indirect quality control of PT sodium lamps.
Cited by 0 works.