The noninvasive measurement technique that combines particle image velocimetry and ultrasound brightness (B)-mode image of scattering particles, referred as Echo-PIV method, was applied to analyze the flow structure of a pump system inside the nuclear reactor model. The fundamental characteristic of the ultrasound image system was quantified using phantom test. The spatial resolution of the ultrasound image system was determined by tracking the movement of a wire phantom along the axial and lateral direction. The conventional PIV method was used to process the consecutive ultrasound images to obtain the 2D instantaneous velocity fields of downstream region of the impeller. The flow rate comparison between the bulk flow rate measurement and Echo-PIV method were performed. This study demonstrated the feasibility of Echo-PIV method for investigating the opaque flow in fluid machinery.