최두열, 정한식, 정효민 et al. · 대한기계학회 춘추학술대회 · 2009

This study was performed to evaluate the theoretical analysis of the mass balance and heat balance, a single effect desalination process by mechanical vapor compression (MVC), and a set of correlations for evaluation of the thermo-physical property of water. The analysis focuses on prediction of specific power consumption for the vapor compression of the desalination process by mechanical vapor compression. A present study was performed the vapor compression ratio 1.24, the suction steam pressure 31.2 kPa (saturation temperature 343.15 K), and discharge pressure 38.6 kPa (saturation temperature 348.15 K). Finally, comparison of the specific energy consumption of the MVC desalination process and the 5 effect thermal vapor compression (MED-TVC) desalination process was evaluated. The choice between the two systems should be done when plant operating parameter and operating cost is considered