상부로부터 공기가 유입되는 챔버형 검사 장비의 내부 유동해석
이형식, 함병철, 이상호 · 대한기계학회 춘추학술대회 · 2005
For inspection machines used in checking intricate devices, the environment inside the machine should be usually maintained with care in order to avoid possible contamination. In this study, internal flow analysis for an inspection machine is done subject to air flowing from the top using steady state condition. From the numerical results, the maximum velocity is found to be 0.97m/s in the vicinity of exits. The average pressure over the workpiece is calculated as 101,317㎩ within 1㎩ difference and the net force on the workpiece found to be 34.6N. Also, it is found that there is almost no swirling flow in front of the workpiece.