단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발

윤병조, 강경호, 어동진 et al. · 유체기계 연구개발 발표회 논문집 · 2004

Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pitot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pitot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80㎜ inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within 10% error of measured data.