The behavior of a liquid film on a solid wall has drawn quite attention in many engineering applications. Our attention has been paid to the thin liquid film subjected to a heat flux from a bounded wall as in a BWR fuel rod. Full-Length BWR fuel rods may experience azimuthal or axial heat flux gradients due to variations of the thermal-hydraulic conditions in the surrounding subchannels caused by either proximity to inserted control blade tip or proximity to the top of part-length rods. Azimuthally or axially non-uniform heat flux gradients may cause the liquid film on the fuel rod surface to rupture by hydrodynamic instability, thereby forming a dry hot spot. The Level Contour Reconstruction Method has been applied to model simplified BWR test problem. The results show that, with sufficient amount of perturbation of the heat flux in the axial or azimuthal direction, a dry hot spot can form which is not the case with uniform heat flux distribution.