지하주차장 PC화 공법 접합부에 대한 구조성능 평가

임재형, 이강민, 문정호 et al. · 대한건축학회지회연합회 논문집 · 2008

An experimental program was initiated to investigate the structural capacity of PC(Precast Concrete) joints used for the underground parking system. Static testing of 14 typical PC joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were subdivided into 5 groups by their joint types. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on 14 PC joints specimens, the PC system used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.

Cited by 0 works.

Authors