니켈-코발트 박막 시편 피로 물성에 대한 연구
전윤배, 안중혁, 박준협 et al. · 대한기계학회 춘추학술대회 · 2009
In this study, fatigue tests were performed for NiCo which is widely used in MEMS devices. Mechanical properties of thin film are important for design the mechanical structure and components. Mechanical properties of thin film are not same as those for bulk materials. Therefore, the production of thin film and the experiment is needed. The width of specimen is 50, 100, 150 ㎛. In the fatigue test of thin film, it is difficult to perform the fatigue test at R=-1. However, the result of the fatigue test at R=-1 should be required when fatigue life prediction is performed. Therefore, in this study, the modified Goodman method, Gerber method and Soderberg methods were be considered to investigate which method is most reasonable when mean stress is considered.
Cited by 0 works.