[연구논문-건축] 볼트 접합 및 프리스트레싱을 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진실험

이동주, 이주동, 오태수 et al. · 대우건설기술 · 2014

In this study, experimental research was carried out to investigate the seismic and structural performance of precast concrete exterior beam-column joint using bolt type connection and prestressing method. A total of five full- scale exterior beam-column joints were constructed and tested under reversed cyclic loading, controlled by displacement. Results of the test are as follows: Energy dissipation capacity and pinching phenomenon of PC beam-column joints showed disadvantageous behavior compared to that of RC beam-column joints. However, ductile capacity of the PC joint was better than the RC joint. Also, yield mechanism concentrated on embedded nuts was suitable as an exterior beam-column joint of Special Moment Frame. Additional application of prestressing method was also very effective to control excessive pinching and cracking in the joint region, and thus improved an overall seismic performance of the PC joint.

Cited by 0 works.

Authors