겨울철 태양열을 이용한 가정용 난방시스템의 실증연구
고원빈, Le Minh Nhut, 박윤철 · 한국태양에너지학회 춘계학술발표회 논문집 · 2014
The system in this study is consisted with 26m2 double tube vacuum collector, 1,200L thermal storage tank and the working fluid controlled by automatic controller with temperature difference between solar collector outlet and collector temperature. Auxiliary heating device is selected oil boiler with 13,000kcal/h capacity. The system is installed residential house located at Jeju City. The heating area of the house is approximately 135 m2. The experiment was conducted during winter season from November to February and energy consumption to the house and energy collected by the solar collector was monitored. As results, the average solar irradiation is about 181W/m2, outdoor temperature is 8.1℃. The total data gathering rate is 77%. Mean heating hour shows 7.7h/day with heating load of the building is 1,973kWh. With that kind of residential house, the solar collector achieved energy from solar about 248kWh with 2.7h/day operating time. The total energy saving of the building by the solar collector shows 12.5% of heating load.
Cited by 0 works.