Studied 41 patients with aseptic instability of hip endoprosthesis SLPS. In order to detection the possible causes of aseptic instability studied medical history, estimated the correctness of the prosthesis component implantation, marked features of revision cases surgery, performed histological examination of soft tissue surrounding the implant. It was revealed that the main causes of instability were an incorrect implantation of endoprosthesis and reaction to the material and the wear products of polyethylene liner. Among the incorrect implantation of endoprosthesis the most significant was high and deep position of cup, incomplete immersion of stem, small size of their. Noted that metallosis and liner wear are present even in the absence of visible changes. To a lesser extent the casues of instability were injury, severe physical stress, obesity, local osteoporosis.