일정 열유속을 가진 사각채널에서 거친 벽면의 수가 열전달에 미치는 효과
배성택, 김명호, 안수환 et al. · 2005
Repeated ribs are used on heat exchanger surfaces to promote turbulence and to enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concerns detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue was tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall had a 45° inclined square rib. Uniform heat flux was maintained on the whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increased with increasing the number of rough walls.
Cited by 0 works.