믹서의 가동 수 및 각도 변화에 따른 유동형 지붕 탱크의 유동특성

김노형 · The KSFM Journal of Fluid Machinery · 2015

In this study, there are 6 mixers that are installed in a 600,000 barrel tank. We identified internal flow characteristics of floating roof tank with varying the number of operation from 4 to 6 because mixer is a variable that influence flow characteristics of the tank. And while varying an angle from Right 60°, Right 30°, Left 30° to Left 60°, we identified internal flow characteristics of the tank. As a result, maximum velocity of flow was 0.02m/s stationarily when we changed the number of operation from 4 to 6. Maximum velocity of flow by change of an angle was from 0.42m/s to 0.47m/s. Therefore, we identified that these factors dont have a great influence on internal flow characteristics of a tank by investigating results with varying the number of operation and an angle.

Cited by 0 works.