고흥항공센터의 전기장 환경 분석
장경덕, 김태윤, 장재웅 et al. · 항공우주기술 · 2013
In this study, the analysis of electromagnetic environment of goheung aviation center was performed. If the test object has restrictions to be tested in indoor test facility, open area test site can be used to perform EMC test. Open area test site shall have no obstacles that can generate or reflect the electric field so as to prevent the measurement result from being influenced by unnecessary field. Goheung aviation center is surrounded by fields, and has no buildings that can reflect electric field, so the center can be a good candidate for open area test site. Ambient noise at Goheung aviation center was measured, and the result show that the center has good electromagnetic environment to perform EMC test for large volume object.