슬관절 전치환술에서 후방십자인대 보존 여부와 대퇴 삽입물 크기의 상관 관계 분석
서재곤, 문영완, 황찬하 et al. · 2006
Purpose: How PCl preservation affects the selection of femoral component size in total knee arthroplasty. Materials and Methods: One hundred and fifty-seven patients, two-hundred and twenty-two knees, underwent total knee arthroplasties with Scorpio®. One hundred and eighteen knees underwent PCL-preserving procedures, and one-hundred and four knees underwent PCL-substituting procedures. For minimization of error, we performed soft tissue balancing and then bone cutting by a Linker system with certain posterior slope (≤3°). We compared the sizes of the femoral components between the PCL-preserving and PCL-substituting procedures in order to determine how flexion gap differences affect femoral component sizes (Wilcoxon signed rank test). Results: With a certain minimal posterior slope (≤3°), the PCL-preservation procedure led to selection of a 2.4 ㎜ smaller femoral component than the PCL substituting procedure (p<0.05). Conclusion: Selection of femoral component size was affected by PCL preservation, and the size of the femoral component was decreased in the PCL preservation group.