청계천 복구에 따른 주변건물의 냉방부하 저감효과에 관한 연구
한수곤, 허정호 · 대한건축학회 학술발표대회 논문집 - 계획계 · 2006
Before Choengye stream was restored, its surrounding area was very hotter than other areas(the Urban Heat Island). So the energy use for the building cooling was seriously enormous. As building cooling energy use emitted heat to the environment, buildings energy use and heat island grew worse. This study was to estimate cooling load reduction by the Choengye stream which was restored in september, 2004. We selected and classified the building sector of the Choengye stream surroundings and simulated the building cooling load by using reports of the Korea Meteorological Administration and field measurement through the TRNSYS 16 program. In result, cooling load was reduced by 15%, and total cooling load reduction was 341.019Mwh in August.