다수대를 이용한 복사관 버너시스템에서 맥동연소기술
조한창, 오혁진 · KOSCO SYMPOSIUM 논문집 · 2011
An experimental study was carried out in a heat treatment furnace to investigate the performance, such as NOx emission, enhancement of heat transfer, system stabilization and etc, of oscillating combustion applied in multi radiant tube burner system. A oscillating controller with solenoid valve were designed and used to control 20 valves. In a test furnace with one burner, NOx emission decreases by 40~50 % in 2.0㎐ and duty ratio 30%. As oscillating combustion was applied in radiant tube burner system, it is found that NOx emission, compared to no oscillation, could be reduced by 20~30% at 2.5㎐ without CO emission. However, as oscillating frequency was increased, effect of abatement of NOx emission is gradually reduced. From the measurement of furnace heating time from 100℃ to 900℃, heat transfer is increased by 4.0% at the oscillation of 2㎐. Temperature distribution of radiant tube surface is more uniform at oscillation of 2㎐ with decrease of the peak temperature and increase of low temperature. From these results, it is confirmed that oscillating combustion is useful in radiant tube burner system.
Cited by 0 works.