РЕЗУЛЬТАТЫ ПРОМЫШЛЕННОЙ ЭКСПЛУАТАЦИИ ПРИБОРА ЭЛЕКТРОМАГНИТНОЙ ОБРАБОТКИ ВОДЫ В СИСТЕМЕ ОБОРОТНОГО ВОДОСНАБЖЕНИЯ ГАЗОПЕРЕРАБАТЫВАЮЩЕГО ЗАВОДА

Д. М. Рунов, Anatoly G. Laptev · 2014

In this article deals with the problem of scale formation on the heat transfer surfaces of the heat exchangers in the system of recycling water supply Gas Processing Plant (GPP) control Tatneftegazpererabotka Republic of Tatarstan due to the supersaturation of water the hardness salts. As a result of scale formation in the heat exchangers occurs undercooling of high-temperature of gas streams, which entails additional material costs for the preparation of the final product. Therefore, in the system of recycling water supply were begun testing of device of electromagnetic treatment of water (EWTD), which was mounted on a common delivery pipe installation gas drying and purification of CO2 (ICDPG). With this pipeline, water is supplied to a group of heat exchangers. Determination of the influence EWTD on the cooling process of the high temperature gas was made on compared temperature regimes of gas flows in two parallel identical operated heat exchangers. Herewith on the first heat exchanger, as for whole group of heat exchangers ICDPG, is fed the treated water, and the second heat exchanger is operated without the electromagnetic treatment of fed water. The initial conditions for the two systems are almost identical - gas and water are served from a single source. Comparison gas temperatures upstream and downstream of the two parallel of identical heat exchangers is showed that in the first heat exchanger is occurs more intense cooling of the high-temperature gas, compared to the heat exchanger, which is used without electromagnetic water treatment. To determine the effect on the efficiency EWTD heat exchangers was made a calculation of the thickness of scum on their heat transfer surfaces on the difference calculated and experimental values of thermal resistance. Calculated value of the thermal resistance is determined by the heat load of the heat exchanger from the heat balance equation, known area of heat exchange and the average temperature pressure. in determining the calculated value of the thermal resistance the heat transfer surfaces by the heat transfer coefficient, one of the values of its denominator is the value of the thickness of the scum Determination of the experimental values of thermal resistance for heat exchangers are made by the standard methods, which are determined by the heat transfer coefficient for the clean surface. According to the obtained values of the thickness of scum in both heat exchangers are determined their efficiency, comparing it is that we can conclude that the use of EWTD increases the efficiency of heat transfer equipment in 5 times. In turn, this allows to significantly reduce material costs for the passage of water through the heat transfer surfaces, i.e. reduce the costs of preparing the final product of the ICDPG.

Cited by 0 works.

Authors