한중환경시 폴리우레탄폼 도포 갱폼 사용에 따른 콘크리트의 온도이력 특성

남경용, 강인선, 이종균 et al. · 대한건축학회 논문집 - 구조계 · 2011

This study is analyzing a member kind after placing concrete, the location-based temperature record, and the strength development, by making insulation gang-form with application of polyurethane form to general gang-form for securing efficient concrete quality in the condition of cold weather. According to our experimental results, the member of general gang-form with curing in the same condition as the actual field didnt drop to under 3℃ until before 24 hours in the early part, but fell to under 0℃ from 36 hours later because a large rise in temperature caused by hydration reaction didnt occur. On the other hand, in case of insulation gang-form, the temperature on the surface and the central part didnt go down to under 3℃ before 12 hours in the early part and didnt fall to under it even until 72 hours after it while the peak temperature went up to 12℃. Thus, it could be known to definitely have excellent insulation effect compared to space heating curing, which is generally performed on the spot. In comparison with space heating curing whose error in curing temperature is big every field, it is judged to likely have great effect on improvement in concrete quality given the work construction in cold weather and on early demolding in a cast during winter.

Cited by 0 works.