하나로 냉중성자원 비핵열부하 추정
박종학, 이기홍, 황동길 · 대한기계학회 춘추학술대회 · 2006
A Cold Neutron Source has been developed to install at HANARO which is a large scale research facility using neutrons. A cold neutron is very useful to investigate the structure or the motion of an amino acid, a protein and a virus. It also can be used to study the structure of polymer, metallic alloy to develop the new materials. To produce cold neutrons, thermal neutrons from a reactor should lose their energy by passing through a cryogenic fluid such as 20K liquid hydrogen or liquid deuterium. For HANARO cold neutron source, a two-phase thermo-siphon system using the liquid hydrogen as a moderator was selected. The moderator is cooled to maintain its liquid state by helium cryogenic refrigerator. The helium refrigerator should have a cooling capacity to cover the non-nuclear heat load as well as nuclear heat load with a sufficient margin. In this study non-nuclear heat load by conduction and radiation due to extreme temperature difference is estimated using commercial CFD code, CFX. According to the results, the non-nuclear heat load doesn’t exceed 300W which is allocated for the non-nuclear heat load of the refrigerator capacity.
Cited by 0 works.