붕소주입탱크 제거에 따른 원전 격납건물 건전성 예비 평가
조종영, 송동수, 변충섭 · 대한기계학회 춘추학술대회 · 2008
Boron Injection Tank(BIT) is a component of the Safety Injection System, which its sole function is to provide concentrated boric acid to the reactor coolant in order to mitigate the consequences of postulated Main Steamline Break accidents. Although BIT plays an important role in mitigating the accident, high concentration of 20,000ppm causes valve leakage, clog of precipitation and continuous heat tracing have to be provided. For the removal of BIT, benchmarking analysis is performed between COPATTA code used in Final Safety Analysis Report and CONTEMPT code to be used this study. CONTEMPT is well compatible with COPATTA. The sensitivity study for integrity is performed for the three cases of full Double Ended Rupture at 102% power with Diesel Generator failure, 3.4㎥ & 2400ppm BIT, 3.4㎥ & 0ppm BIT and no volume of BIT. The results show that the deactivation of BIT is plausible for success.