Использование ларингеальной маски для вентиляционной поддержки при фибробронхоскопиях у детей

А. М. Естехин, П. И. Миронов, А. А. Гумеров · Медицинский вестник Башкортостана · 2011

The study was designed as a prospective, non-randomized, single center, controlled investigation. The aim of this work was a comparison assessment of gaseous exchange in anesthetically managed bronchoscopical manipulations with tracheal intubation and laryngeal mask application. The research involved 86 patients at the age of 10 months 6 years (mean age 41.4+7.2 months) with body weight 8-25 kg (mean body weight 16.2+3.1 kg). Duration time of bronchoscopy procedure was 5-28 minutes (mean duration time 11.3+2.4 minutes). Depending on the method of airway patency maintaining, patients were divided into two groups: in group 1 (41 children) general anesthesia with propofol, myorelaxation, suxametonium, traсheal intubation and subsequent bronchoscopy were conducted; in group 2 (45 children) general anesthesia with propofol, myorelaxation, suxametonium and succeeding laryngeal mask application were performed. In both groups, 2% lidocaine solution as a local anesthetic was used. Results of the study indicate laryngeal mask application for respiratory tract patency maintaining in the course of bronchoscopy to have comparable outcomes as contrasted to tracheal intubation.

Cited by 0 works.

Authors