모사 배기관내 연소 에어로졸의 거동
한용택, 배귀남, 이진하 et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 2006
In this study, a combustion aerosol generator system was designed and developed and several parametric study was performed experimentally. Particle size distributions were measured using a scanning mobility particle sizer(SMPS). An electric furnace was utilized to control the temperature of simulated gas. The particle size distribution and temperature along with the simulated exhaust pipe was measured. There could be several mechanisms for particle movement and generation, and we thought that thermophoresis, nucleation, and condensation could be generated for the behavior of particles in this system. The size distribution of aerosols generated from the combustion aerosol generator was highly dependent on the combustion air, and it was insensitive to other parameters. Particle formation in a tube furnace was observed when the furnace temperature were higher than 450℃. In the simulated exhaust pipe, the particle loss due to thermophoresis was also monitored at the high temperature.