광학입자센서 내 노즐형상과 입자 크기에 따른 측정효율 변화에 대한 실험 및 시뮬레이션
김영길, 아툴 쿨카르니, 전기수 et al. · 대한기계학회 춘추학술대회 · 2008
The OPS (optical particle sensor) based on light scattering principle are widely used in clean rooms and for the atmospheric environment monitoring applications. Its popularity lies in its real time measurement ability with no physical contact with the particles under measurement. The detection efficiency of the OPS is mainly governed by the scattered light intensity, which strongly depends on particle size and its velocity in the detection area. In this study, we carried out simulation and experiments to evaluate the effect of nozzle size and shape (geometry) on detection efficiency of the OPS. A commercial computational fluid dynamics software FLUENT was used to simulate the flow field and particle trajectories. The effect of nozzle size and shape is evaluated as the count mode of scattering intensity with particle size (300, 500, 700 ㎚) experimentally. Simulated particle velocities were compared with experimental results and found within limit.
Cited by 0 works.