Unlike impinging jet test was conducted to understand combustion instability occurred in the previous ground hot-firing test of 500 N scale green hypergolic bipropellant thruster. Unlike impinging jet test was performed to explore injection characteristics and combustion phenomenon. Differential pressure of the nozzle elements was selected with 2 bar, 6 bar and 10 bar. Ignition delay was measured depend on the variables around 10~76 ㎳. At the differential pressure 6 bar which is same as design pressure drop of 500N Injector, short ignition delay around 10 ㎳ and stable combustion were investigated. At the differential pressure 10 bar simulating starting characteristic of the thruster, however, relatively long ignition delay and combustion instability were observed.