원전 기기 내부구조물에 대한 구조건전성평가

이한희, Jin-Yong Choi · 대한기계학회 춘추학술대회 · 2007

The internal structure is subjected to dynamic analysis due to the structural integrity. The internal structure shall be installed in the vertical hole call IR1 of reactor core. In order to verify the deflection of the internal structure, the mode and response spectrum analysis of the internal structure was performed. The natural frequency of the internal structure is 11.6 ㎐(mode 1 and 2) and deflections of the internal structure are less than values of allowable design (3.2 ㎜).