음투과성 플레넘을 이용한 에어컨 실내기의 소음평가

정인화, 진심원, 이창선 et al. · 대한설비공학회 학술발표대회논문집 · 2001

In this study, acoustically transparent plenum is used in rating the noise of split type air conditioner indoor unit. Until now, it has been general to measure noise level at operation point for selecting low noise fan and fan system. Comparing with this, the method using plenum is advantageous in that it gives noise data on PQ curve. However, this method can be erroneous because it is based on assumption that plenum have no influence on the noise of which the origin is aeroacoustic, and also there are some problems in connected with its complicated test procedure. So in this study acoustical transparency of the plenum is verified, and possible errors that can be occurred during test procedure are discussed.