고온용 증기공급 히트펌프를 위한 냉매 선정

고희환, 정동진, 임호진 · 대한설비공학회 동계학술발표회 논문집 · 2014

The representative of refrigerant used as a working fluid in chiller and heat pump is CFCs, HCFCs, HFCs. There are numerous types of 4th generation refrigerant, representatively HFO. In order to select a refrigerant for the high temperature heat pump for steam supply, energy efficiencies of refrigerant, low GWP, ODP, safety, cost, LCCP (Life Cycle Climate Performance) have to be considered. R-245fa has been selected as refrigerant used for the high temperature heat pump for steam supply. Following things are additionally reflected in this study. If the characteristic of the next generation HFO-based refrigerant could be stabilized, it is possible to replace the HFO-based refrigerant with similar refrigerant. The development cost is reasonable because base research for evaluating the refrigerant performance had been conducted. The safety of refrigerant is matured in terms of long term risk management.

Cited by 0 works.